The device is equipped with a temperature calibration feature. In general, our probes maintain accuracy and seldom require recalibration. However, if you suspect a temperature discrepancy, you can recalibrate using the following steps:
1. Create ice cubes in the refrigerator using distilled or purified water.
2. Fill an insulated cup with the ice cubes and add a suitable amount of water—enough to cover the ice without excess.
3. Turn on the device, immerse the probe into the ice water, and stir continuously for 1 minute.
4. Wait for the temperature reading to stabilize. Calibration is unnecessary if the temperature is within the range of -0.3 °C to 0.3 °C. If the temperature falls outside the range of -2 °C to 2 °C, recalibration is not possible.
5. Simultaneously press and hold the °C/°F button and the LOCK button for 5 seconds. The display will flash ""CAL,"" indicating calibration mode. Upon completion, the display will flash ""Suc."" If ""Err"" appears on the screen, repeat the calibration process.